西安交通大学《发电厂电气设备》在线作业

奥鹏西安交通大学平时在线作业

{"P1":"E0143188-D36F-4212-A9B1-33494D4594D2","P2":"西交《发电厂电气设备》在线作业","data":[{"I1":"cc9974c1-ef85-4242-97f6-4e6f19845f02","I2":["大中型发电厂,特别是火力发电厂的厂用电备用方式,常利用( )方式"],"I3":1,"I6":["明备用","暗备用","与系统相连的主变兼作备用"],"I15":["0"]},{"I1":"bc5920e3-5133-4a14-9926-bda7aa486959","I2":["变压器的最大效率发生在________。[ ]"],"I3":1,"I6":["=1","=0.6-0.8"],"I15":["1"]},{"I1":"af4cda2b-b5c6-419f-8d7d-461cd10c0706","I2":["下面对发电厂的描述最准确的是()。"],"I3":1,"I6":["火电厂因其耗能大,效率低,已经不承担主要电力负荷","我国的水力发电承担主要电力负荷,我国的水力资源已经得到大力开发","凝汽式电厂效率高于热电厂,因此我国正大力发展凝汽式大型火电厂","水电厂运行灵活,效率高,且具有调相、调峰、事故备用的功能,可提高电网运行的灵活性、可靠性"],"I15":["3"]},{"I1":"5ce5e0e9-bc2f-4e50-a0c2-3faf46282f7b","I2":["某变电所220千伏配电装置的布置形式为两组母线上下布置,两组母线隔离开关亦上下重叠布置而断路器为双列布置,两个回路合用一个间隔。这种布置方式称为( )。"],"I3":1,"I6":["半高型布置","普通中型布置","分相中型布置","高型布置"],"I15":["3"]},{"I1":"f4e1aae1-e9d3-4fef-ac14-ef1390237b99","I2":["导体长期发热的稳定温升与()有关。"],"I3":1,"I6":["起始温升","起始温升和载流量","载流量","环境温度"],"I15":["2"]},{"I1":"f8c7429e-fc16-491c-8c3e-cb0e8188f391","I2":["中性点经消弧线圈接地一般采用( )"],"I3":1,"I6":["欠补偿","全补偿","过补偿","不补偿"],"I15":["2"]},{"I1":"52d028d1-116e-4d39-9614-fc8546d2b3ae","I2":["一般说来,核电厂与或火电厂相比造价(),运行成本()。"],"I3":1,"I6":["高;低","高;高","低;高","低;低"],"I15":["0"]},{"I1":"3747e52a-9912-4463-8e3c-acdd49e47fce","I2":["在10KV出线上,电流互感器通常( )。"],"I3":1,"I6":["三相式星形接线","两相式不完全星形接线","三相式三角形接线","单相式接线"],"I15":["1"]},{"I1":"109acc17-b9cc-4196-b0dc-1cb07ab43485","I2":["不同回路长期持续工作电流应根据(  )确定。"],"I3":1,"I6":["单回路按最大负荷电流(包括事故情况下转移过来的电流);","双回路按最大负荷电流的1.8倍;","母联断路器按最大元件负荷电流的2倍;","单台变压器回路按额定电流的1.3~2.0倍。"],"I15":["0"]},{"I1":"05700793-216d-481a-b354-0f623be61887","I2":["在交流电路中,弧电流过零值之后,当弧隙的恢复电压( )弧隙击穿电压时,将会使电弧熄灭。"],"I3":1,"I6":["大于","等于","小于","正比于"],"I15":["2"]},{"I1":"66be6913-ab6b-42eb-af79-b4ea3a55d581","I2":["多油断路器中油的用途是( )"],"I3":1,"I6":["灭弧介质和冷却介质","灭弧介质及触头间隙绝缘介质","灭弧介质以及触头间隙、带电部分与地之间的绝缘介质","其他都不对"],"I15":["2"]},{"I1":"65bb25b1-389e-4277-bc61-bfbd43a61a93","I2":["以下不属于二次设备的是( )"],"I3":1,"I6":["仪用互感器","测量表计","继电保护及自动装置","变压器"],"I15":["3"]},{"I1":"e732cc67-e755-4498-86b5-e9302bf49ece","I2":["选择悬式绝缘子时不需考虑(  )。"],"I3":1,"I6":["额定电压","机械荷载","动稳定","绝缘水平"],"I15":["2"]},{"I1":"c0aa2e0a-8c98-4a4f-8d1b-e54c23f7b6af","I2":["多油断路器中油的用途是()"],"I3":1,"I6":["灭弧介质","灭弧介质和绝缘介质","绝缘介质","其他都不对"],"I15":["1"]},{"I1":"65ca140c-2c90-448b-a7bb-e83539295ff0","I2":["信号装置按用途来分,不包括( )"],"I3":1,"I6":["事故信号","预告信号","位置信号","闪烁信号"],"I15":["3"]},{"I1":"afacce82-3833-4db1-851d-580ab8296ccb","I2":["断路器的开断时间是指从接受分闸命令瞬间起到( )"],"I3":1,"I6":["所有电弧触头均分离的瞬间为止","各极触头间电弧最终熄灭为止","首相触头电弧熄灭为止","主触头分离瞬间为止"],"I15":["1"]},{"I1":"bcd72521-6838-44ff-9310-0a4b0ccfee0a","I2":["220kv及以上变电所所用变压器接线组别宜采用( )"],"I3":1,"I6":["ygn12","Dd12","Dyn11","Yd11"],"I15":["2"]},{"I1":"a60f963b-07e7-47ca-b奥鹏西安交通大学平时在线作业856-2feb8aefe90a","I2":["减小矩形母线应力的最有效方法是( )"],"I3":1,"I6":["改变母线的布置","增大母线截面","减少同一相中两个相邻绝缘子间的距离","增加母线相间距离"],"I15":["2"]},{"I1":"815a93bc-73d4-4b76-bb40-724725d569e1","I2":["旁路回路的持续工作电流为()。"],"I3":1,"I6":["需旁路的回路最大额定电流","需旁路的主变压器回路额定电流","需旁路的电源回路额定电流","需旁路的出线回路最大负荷电流"],"I15":["0"]},{"I1":"428bb0de-09dc-4e23-b88e-58f894a31c7a","I2":["无汇流母线接线没有得是( )桥"],"I3":1,"I6":["桥形接线","角形接线","星形接线","单元接线"],"I15":["2"]},{"I1":"ace8834c-6859-4847-ac34-ee0c9a170fca","I2":["配电装置的选择,通常要进行技术经济比较确定,一般( )电压等级宜采用屋内配电装置。"],"I3":1,"I6":["35kv及以下","35kv及以上","10kv及以上","110kv及以下"],"I15":["0"]},{"I1":"a30ec473-580a-4f62-b98a-847afdb876d8","I2":["采用双母线同时运行的双母线接线,具有单母线分段接线的特点,( )。"],"I3":1,"I6":["因此双母线接线与单母线分段接线是等效的","但单母线分段接线具有更大的运行灵活性","并且两者的设备数量一样","但双母线接线具有更大的运行灵活性"],"I15":["3"]},{"I1":"ad923049-af32-4bba-9f4d-a9d39f06b64d","I2":["不属于电流互感器常用的接线方式的是( )"],"I3":1,"I6":["单相接线","星形接线","不完全星形接线","星形接线"],"I15":["3"]},{"I1":"08f88c97-0b47-42f5-a941-3ef56a31d6ce","I2":["检验高压断路器开断能力的开断电流应取()。"],"I3":1,"I6":["断路器实际开断时间的短路电流","短路冲击电流","短路动稳定电流","额定短路电"],"I15":["0"]},{"I1":"35ea3228-fd7b-40b9-902b-dd54eb075ab0","I2":["水平排列、间距相同的三根导体,两边分别为流过A相、C相,中间B相电流。三相对称短路时,受力最大的一相为()。"],"I3":1,"I6":["A相","B相","C相"],"I15":["1"]},{"I1":"d6985399-bd9e-4155-b805-a8e07a6c66fc","I2":["外桥接线适合于( )"],"I3":1,"I6":["线路较短、变压器需要经常切换的场合","线路较长、变压器不需要经常切换的场合","线路较多、只有两台变压器的场合","只有两条出线、变压器台数较多的场合"],"I15":["0"]},{"I1":"d12554bc-acd0-443a-b801-0dd8e38d3562","I2":["( )接线在出线断路器检修时,会中断该回路供电。"],"I3":1,"I6":["单母线分段带旁路","双母线分段带旁路","二分之三接线","双母线分段"],"I15":["3"]},{"I1":"a757f744-d3e8-4488-ba50-3deba3c84bed","I2":["下面关于高压电器过载能力说法正确的是(  )。"],"I3":1,"I6":["1.05倍电器额定电流","1.3倍电器额定电流","2倍电器额定电流","没有明确的过载能力"],"I15":["3"]},{"I1":"70349680-8fb8-4445-bf13-ef0eadc69fd6","I2":["电能与其他形式的能源相比,其特点不包括( )"],"I3":1,"I6":["便于大规模生产和远距离输送","方便转换和易于控制","可以大量储存","损耗小"],"I15":["2"]},{"I1":"b46b1f46-3445-49ed-9092-5f7b5c33dc84","I2":["带电抗器出线回路的持续工作电流为(  )。"],"I3":1,"I6":["线路最大负荷电流","电抗器额定电流","1.3倍线路最大负荷电流","0.8倍电抗器额定电流"],"I15":["1"]},{"I1":"a426f9b8-1ea6-4a55-a10e-f524bd236103","I2":["发电厂是把一次能源转换成电能的工厂。( )"],"I3":3,"I6":["错误","正确"],"I15":["1"]},{"I1":"4394fd72-6d0b-4778-9455-8cc828a7808d","I2":["隔离开关不允许带负荷操作。"],"I3":3,"I6":["错误","正确"],"I15":["1"]},{"I1":"840992f9-d5f1-4bcf-841d-4aed01f47ce3","I2":["选择变压器时,一般的,对于较重要负荷,要考虑2台以上变压器,变压器容量按70%原则确定。( )"],"I3":3,"I6":["对","错"],"I15":["0"]},{"I1":"a5ecb427-6bd5-4ef6-96d7-27be8a207efa","I2":["电力系统中的发电机及各电压等级的变压器的中性点,都是电力系统的中性点。( )"],"I3":3,"I6":["错误","正确"],"I15":["1"]},{"I1":"5464055a-520f-4390-9368-e7b783f83ba2","I2":["按照经济电流密度选择导体截面,可使导体的年计算费用最低,但在导体运行时可能超温。()"],"I3":3,"I6":["错误","正确"],"I15":["1"]},{"I1":"68cb6e63-6854-4e0a-aaeb-135f381de0d2","I2":["电气主接线是电力系统网络的重要组成部分。它直接影响系统的可靠性、灵活性,对电器的选择、电气设备布置、继电保护设置、自动装置配置等都有决定性的关系。"],"I3":3,"I6":["对","错"],"I15":["0"]},{"I1":"9ddf4364-a656-42d7-b73f-2e83266c043a","I2":["当海拔升高,电器的绝缘水平降低;当环境温度升高,电器的允许电流减小。"],"I3":3,"I6":["错误","正确"],"I15":["1"]},{"I1":"a6ae91ac-2c16-46c0-8367-ecd39c1e4deb","I2":["内桥接线适用于线路较长、容量较小和变压器需经常切换运行方式的装置中。( )"],"I3":3,"I6":["错误","正确"],"I15":["0"]},{"I1":"4f0b4cff-6792-4d0d-8da0-3aa4d97da238","I2":["发电厂的厂用电备用方式,采用明备用方式与暗备用方式相比,厂用工作变压器的容量较小。"],"I3":3,"I6":["对","错"],"I15":["0"]},{"I1":"7236604f-547b-41cd-86ba-de18ee257434","I2":["为了提供3次谐波电流通路,大型芯式电力变压器的高、低压绕组一般有△接法的绕组。()"],"I3":3,"I6":["错误","正确"],"I15":["1"]},{"I1":"fbe0cfc5-3fa0-4fb2-81e4-260090df68c4","I2":["电气设备选择的一般条件是按正常工作条件选择电气设备、按短路状态校验。( )"],"I3":3,"I6":["错误","正确"],"I15":["1"]},{"I1":"d4f915bb-ce39-4aa2-a35e-9199e56cbd11","I2":["对称三相电路丫连接时,线电压为相电压的√3倍。( )"],"I3":3,"I6":["错误","正确"],"I15":["1"]},{"I1":"5eec6c77-68e4-4b3e-88b0-06ed55bdb41c","I2":["电抗器垂直布置时B相应放在上下两项之间。()"],"I3":3,"I6":["错误","正确"],"I15":["1"]},{"I1":"184de057-a474-48f6-8df2-df97e41ae11d","I2":["火电厂的电能生产过程概括的说是把煤中含有的化学能转变为电能的过程。()"],"I3":3,"I6":["错误","正确"],"I15":["1"]},{"I1":"0eaa7fe0-8208-4a36-8638-3c980ba542f3","I2":["习惯上所说的变电所主要指升压变电所。( )"],"I3":3,"I6":["错误","正确"],"I15":["0"]},{"I1":"473b783b-1f3e-42a1-9f40-c38110ca6360","I2":["电能向远距离用户区输送时,为了减少电能损失,应在发电厂将电能降压。( )"],"I3":3,"I6":["错误","正确"],"I15":["0"]},{"I1":"07b6fac1-f548-4336-be00-86c235d81031","I2":["电抗器品字形布置时不应将A、C相重叠在一起。()"],"I3":3,"I6":["错误","正确"],"I15":["1"]},{"I1":"a306918f-eb22-4e1d-a45a-3a76dafd6cf4","I2":["电气主接线图一般画成单线图,仅在三相连接设备不完全相同时,才局部画出三相图。( )"],"I3":3,"I6":["错误","正确"],"I15":["1"]},{"I1":"8ebdee05-3558-4508-ab76-c9b8e2fe6f95","I2":["设计电气主接线时,当可靠性和经济性发生矛盾时,首先满足可靠性。"],"I3":3,"I6":["错误","正确"],"I15":["1"]},{"I1":"595ed011-3cd2-4670-9838-92a6b7718658","I2":["主接线的可靠性越高越好。()"],"I3":3,"I6":["错误","正确"],"I15":["0"]}]}

提供优质的教育资源

公众号: 超前自学网